Generators that start when the mains don't.
A generator is only worth having if it runs on the one night you need it. We service, test and repair them so it does.
Generator down?
Call now. Tell us what it's doing and we'll tell you what we can do about it, and how soon.
0472 590 563Service due?
Send us the details and we'll come back with a time and a price. Or put it on a plan and stop thinking about it.
Book a service
What's it doing?
Most generator faults come down to a short list of causes. Here's what we usually find.
It won't start
Usually the start battery or its charger. Sometimes it's fuel, or a shutdown that was never reset after the last fault.
It starts, then shuts down
Something is tripping a protection: low oil pressure, high coolant temperature, overspeed, or a sensor that's failed.
It runs, but there's no power
Often the voltage regulator, a tripped breaker or a fault in the alternator. The engine is fine and the electrical side isn't.
It didn't take over in the outage
That points to the automatic transfer switch, its settings, or the way it senses mains. This is electrician's work, and we're licensed for it.
It's surging or hunting
Typically fuel supply, blocked filters or the governor. Leave it and it gets worse under load.
There's an alarm on the controller
Take a photo of the screen and call us. The code usually tells us what to bring.
Not on the list? Call anyway. We'd rather hear about it early.
Three ways to keep it ready.
Pick what suits how your generator is used. Every option is quoted for your generator, so you know the cost before we start.
| One-off serviceYou just need it done. | Standby planFor backup generators that sit and wait: farms, cold rooms, offices, homes. | Prime power planFor generators that run every day. | |
|---|---|---|---|
| Oil and filter service | Once | Every 12 months | By run hours |
| Inspection and test run | With the service | Every 6 months | Every visit |
| Load bank test | Add it if you want it | Every 12 months | Every 12 months |
| Transfer switch and blackstart test | Add it if you want it | Every 12 months | Where one is fitted |
| Written report | |||
| We book the visits and remind you | Not included | ||
| Front of the queue for breakdowns | Not included |
One-off service
You just need it done.
- Oil and filter service
- Inspection and test run
- Written report
- Add a load bank or transfer switch test if you want one
Standby plan
For backup generators that sit and wait: farms, cold rooms, offices, homes.
- Inspection and test run every 6 months
- Oil and filter service every 12 months
- Load bank test every 12 months
- Transfer switch and blackstart test every 12 months
- Written report each visit
- We book the visits and remind you
- Front of the queue for breakdowns
Prime power plan
For generators that run every day.
- Oil and filter service by run hours
- Inspection and test run every visit
- Load bank test every 12 months
- Written report each visit
- We book the visits and remind you
- Front of the queue for breakdowns
For plan customers, we'll set up a schedule of fees with you before any work starts, so there are no surprises on an invoice.
The work, then the proof.
On a service
- Engine oil and oil filter changed
- Fuel filter and air filter replaced
- Coolant, belts and hoses checked
- Start battery tested, and replaced when it's due
- Controller, alarms and safety shutdowns checked
On a test
- Load bank test up to full rated load
- Automatic transfer switch tested
- Blackstart test: we drop the mains and watch it take over
- Thermal imaging of switchboards and connections
- Generator
- 100 kVA diesel, standby
- Test
- Load bank, stepped to full rated load
| Load | kW | Min | Hz | Coolant |
|---|---|---|---|---|
| 25% | 20 | 15 | 50.1 | 74°C |
| 50% | 40 | 15 | 50.0 | 80°C |
| 75% | 60 | 30 | 50.0 | 84°C |
| 100% | 80 | 60 | 49.9 | 88°C |
Every visit ends with a written report: what we did, what the readings were, and anything to fix before it becomes a breakdown.
Buying one? Here's how it goes.
We'll tell you honestly if yours is worth repairing first. If it isn't, this is the process.
We measure your load
We work out what your site actually draws, so you don't pay for a generator that's too big or get caught with one that's too small.
We source the generator
Standby or prime power, single or three phase, from Australian suppliers. You get a fixed quote.
We install it
Transfer switch, cabling and switchboard work, all done by licensed electricians.
We prove it works
A load test before handover, your staff shown how to run it, and the first service booked in.
Most generators only get noticed on the day they don't start. Our job is to make sure that day never comes.
Cannon Energy is a licensed electrical contractor, and with generators that matters. The fault is often in the transfer switch, the switchboard or the cabling, and we're licensed to fix all of it. Nothing gets handed to someone else.
We're a small team, so you'll deal directly with the owner. You'll get a straight answer about what your generator needs, and what it doesn't.
ShaneOwner, Cannon Energy

- Type
- Generator service, repairs and sales
- Duty
- Standby and prime
- Phase
- 1 and 3
- Contractor lic.
- QLD 90403
- ABN
- 56 606 530 447
- Service area
- South East QLD
- After hours
- Callouts available
Sheds, panels and switchboards.
Poultry and swine farms
A lot of our work is on farms, where a generator that doesn't start puts stock at risk. We look after the rest of the shed too.
- Shed controllersSkov, Big Dutchman, Rotem, Hired-Hand and others
- VentilationFans, heaters and climate control
- AlarmsTemperature, level and power alarms, paging, remote monitoring
- Motors and drivesMotors, variable speed drives, winches
- Feed and waterFeed lines, bore pumps, filtration, level monitoring
- LightingPoultry lighting and dimmer cabinets
- Audits and new shedsWind speed, light and smoke testing. Full electrical fit-outs.
We also do solar and batteries, EV chargers and general electrical work for homes and businesses.
Control panels and switchboards
Our own range of ready-built shed panels, in single phase or three phase, with Schneider or LS gear, IP66 enclosures and engraved labels. Every panel is built to order, so order early for the quickest turnaround.
- Inlet Controller 3240Opens and closes minimum ventilation inlets and tunnel inlets
- Line Winch ControllerRaises and lowers ten feed, drink and perch lines
- Feed Line ControllerSelects which sensor runs each of four feed lines
- Custom panelsBuilt to suit any poultry or swine shed controller
- SwitchboardsMain distribution boards, meter panels and anything else you need
Call, or send us the details.
0472 590 563- cannonenergyco@gmail.com
- Hours
- Monday to Friday, 7am to 5pm
- After hours
- Breakdown callouts, and weekend on-call plans
- Area
- Brisbane and South East Queensland